The "Standard" System Specifications

A complete "Installation, Operation and Maintenance" instruction manual is included and also contains burner system electrical schematics and Afterburner Data Report. Constructed to comply with OSHA, NEC & NFPA.

 

FUEL REQUIREMENTS:
Natural Gas (1,050 BTU/cu. ft.) 1 1/4" supply line @ 1 PSI. LPG may be used but must be specified at time of order.

 

ELECTRICAL:
Standard supply to the control panel is 120 VAC, 1 ph. A 20 AMP circuit should be dedicated for this service.

 

AIR REQUIREMENTS:
Minimum 1/2" line @ 90 PSI.

 
Text/HTML
  LOAD AREA
DIMENSIONS
OVERALL FURNACE
DIMENSIONS
MAIN BURNER
TYPICAL INPUT
MAIN BURNER
MAX. INPUT
AFTER
BURNER
MAX. INPUT
MIN. GAS
PRESS.
REQ.

MODEL LW LD LH A B C D E BTU/HR* BTU/HR BTU/HR†

PSIG

PBF-36 S 48" 36" 36" 126" 61" 80" 78" 150" 535,000 750,000 690,000 1
PBF-48 S 48" 48" 36" 126" 61" 91" 78" 150" 550,000 750,000 690,000 1
PBF-60 S 60" 48" 36" 126" 73" 91" 78" 150" 565,000 750,000 690,000 1
PBF-80 S 60" 48" 48" 144" 73" 91" 86" 158" 585,000 750,000 690,000 1

 

Specifications subject to change without notice. Check with manufacturer for critical specification requirements.
* Actual fuel consumption will vary with operating conditions. † Based on Category I Afterburner, Category II will be higher.