Flash Fire Dewax System Specifications
Each FlashFire Dewax SYSTEM is engineered specifically to the customers requirements. Shell size, quantity to be processed per day, quantity of wax involved etc. all factor into the design of each SYSTEM.
The FlashFire Dewax SYSTEM utilizes the “NEW GENERATION” furnace specification. In addition the temperature controller is upgraded to the Multiple Program Temperature Controller to allow a wide selection of process cycles and profiles. Also the Afterburner is engineered specifically to the customer work load and an Afterburner Data Report is included to assist in Air Quality Permit application.
A complete “Installation, Operation & Maintenance” manual is provided which includes electrical schematics for the burner, control and PLC systems, inert gas system, air system, and extinguishing chamber heater system. Also included is a full specification sheet, control fuel train diagram and Afterburner Data Report. Also schematics are included for any options. Constructed to comply with OSHA, NEC & NFPA.
FUEL REQUIREMENT:
Natural Gas (1,050 BTU/cu.ft.) is standard, 1 1 / 2 ” supply line @ 1 PSI. LPG may be used but must be specified at the time of order.
ELECTRICAL:
230 VAC, 1 ph., 50 AMP dedicated circuit. Please specify other voltage requirements.
AIR:
1″ line supply @ 90 PSI.
INERT GAS:
Any inert gas (Argon, CO2 , Nitrogen), 1 / 2 ” line supply @ 40 PSI.
THE FLASHFIRE DEWAX SYSTEM OPTIONS. Many options are available which can make this furnace as sophisticated as you need it to be.
- TEMPERATURE RECORDERS
- OXYGEN ANALYZER
- FOOT PEDAL DOOR OPERATOR
- FM or IRI SAFETY FUEL TRAIN
- HIGH LIMIT TEMPERATURE PROTECTION
- CONTROL PANEL COOLER