“New Generation” Specifications
A complete “Installation, Operation and Maintenance” instruction manual is included and also contains burner system electrical schematics and Afterburner Data Report. Constructed to comply with OSHA, NEC & NFPA.
FUEL REQUIREMENTS:
Natural Gas (1,050 BTU/cu. ft.) 1 1/4″ supply line @ 1 PSI. LPG may be used but must be specified at time of order.
ELECTRICAL:
Standard supply to the control panel is 120 VAC, 1 ph. A 20 AMP circuit should be dedicated for this service.
AIR REQUIREMENTS:
Minimum 1/2″ line @ 90 PSI.
THE “NEW GENERATION” SYSTEM OPTIONS
Many options are available which can make this furnace as sophisticated as you need it to be.
- TEMPERATURE RECORDERS
- OXYGEN ANALYZER
- MULTIPLE PROGRAM CONTROLLER
- FM or IRI SAFETY FUEL TRAIN
- HIGH LIMIT TEMPERATURE PROTECTION
- CONTROL PANEL COOLER
LOAD AREA DIMENSIONS |
OVERALL FURNACE DIMENSIONS |
MAIN BURNER TYPICAL INPUT |
MAIN BURNER MAX. INPUT |
AFTER BURNER MAX. INPUT |
MIN. GAS PRESS. REQ. |
|||||||
MODEL | LW | LD | LH | A | B | C | D | E | BTU/HR* | BTU/HR | BTU/HR† | PSIG |
PBF-36 NG | 48″ | 36″ | 36″ | 129″ | 65″ | 90″ | 84″ | 156″ | 570,000 | 1,000,000 | 1,050,000 | 1 |
PBF-48 NG | 48″ | 48″ | 36″ | 129″ | 65″ | 103″ | 84″ | 156″ | 585,000 | 1,000,000 | 1,050,000 | 1 |
PBF-60 NG | 60″ | 48″ | 36″ | 129″ | 77″ | 103″ | 84″ | 156″ | 600,000 | 1,000,000 | 1,050,000 | 1 |
PBF-80 NG | 60″ | 48″ | 48″ | 135″ | 77″ | 103″ | 90″ | 162″ | 620,000 | 1,000,000 | 1,050,000 | 1 |
PBF-100 NG | 60″ | 60″ | 48″ | 135″ | 77″ | 115″ | 90″ | 162″ | 650,000 | 1,000,000 | 1,050,000 | 1 |
Specifications subject to change without notice. Check with manufacturer for critical specification requirements.
* Actual fuel consumption will vary with operating conditions.
† Based on Category II Afterburner, Category III will be higher.