“New Generation” Specifications

A complete “Installation, Operation and Maintenance” instruction manual is included and also contains burner system electrical schematics and Afterburner Data Report. Constructed to comply with OSHA, NEC & NFPA.

FUEL REQUIREMENTS:
Natural Gas (1,050 BTU/cu. ft.) 1 1/4″ supply line @ 1 PSI. LPG may be used but must be specified at time of order.

ELECTRICAL:
Standard supply to the control panel is 120 VAC, 1 ph. A 20 AMP circuit should be dedicated for this service.

AIR REQUIREMENTS:
Minimum 1/2″ line @ 90 PSI.

THE “NEW GENERATION” SYSTEM OPTIONS

Many options are available which can make this furnace as sophisticated as you need it to be.

  • TEMPERATURE RECORDERS
  • OXYGEN ANALYZER
  • MULTIPLE PROGRAM CONTROLLER
  • FM or IRI SAFETY FUEL TRAIN
  • HIGH LIMIT TEMPERATURE PROTECTION
  • CONTROL PANEL COOLER
LOAD AREA
DIMENSIONS
OVERALL FURNACE
DIMENSIONS
MAIN BURNER
TYPICAL INPUT
MAIN BURNER
MAX. INPUT
AFTER
BURNER
MAX. INPUT
MIN. GAS
PRESS.  REQ.
MODEL LW LD LH A B C D E BTU/HR* BTU/HR BTU/HR† PSIG
PBF-36 NG 48″ 36″ 36″ 129″ 65″ 90″ 84″ 156″ 570,000 1,000,000 1,050,000 1
PBF-48 NG 48″ 48″ 36″ 129″ 65″ 103″ 84″ 156″ 585,000 1,000,000 1,050,000 1
PBF-60 NG 60″ 48″ 36″ 129″ 77″ 103″ 84″ 156″ 600,000 1,000,000 1,050,000 1
PBF-80 NG 60″ 48″ 48″ 135″ 77″ 103″ 90″ 162″ 620,000 1,000,000 1,050,000 1
PBF-100 NG 60″ 60″ 48″ 135″ 77″ 115″ 90″ 162″ 650,000 1,000,000 1,050,000 1

 

Specifications subject to change without notice. Check with manufacturer for critical specification requirements.
* Actual fuel consumption will vary with operating conditions.
† Based on Category II Afterburner, Category III will be higher.