The “Standard” System Specifications
A complete “Installation, Operation and Maintenance” instruction manual is included and also contains burner system electrical schematics and Afterburner Data Report. Constructed to comply with OSHA, NEC & NFPA.
FUEL REQUIREMENTS:
Natural Gas (1,050 BTU/cu. ft.) 1 1/4″ supply line @ 1 PSI. LPG may be used but must be specified at time of order.
ELECTRICAL:
Standard supply to the control panel is 120 VAC, 1 ph. A 20 AMP circuit should be dedicated for this service.
AIR REQUIREMENTS:
Minimum 1/2″ line @ 90 PSI.
LOAD AREA DIMENSIONS |
OVERALL FURNACE DIMENSIONS |
MAIN BURNER TYPICAL INPUT |
MAIN BURNER MAX. INPUT |
AFTER BURNER MAX. INPUT |
MIN. GAS PRESS. REQ. |
|||||||
MODEL | LW | LD | LH | A | B | C | D | E | BTU/HR* | BTU/HR | BTU/HR† | PSIG |
PBF-36 S | 48″ | 36″ | 36″ | 126″ | 61″ | 80″ | 78″ | 150″ | 535,000 | 750,000 | 690,000 | 1 |
PBF-48 S | 48″ | 48″ | 36″ | 126″ | 61″ | 91″ | 78″ | 150″ | 550,000 | 750,000 | 690,000 | 1 |
PBF-60 S | 60″ | 48″ | 36″ | 126″ | 73″ | 91″ | 78″ | 150″ | 565,000 | 750,000 | 690,000 | 1 |
PBF-80 S | 60″ | 48″ | 48″ | 144″ | 73″ | 91″ | 86″ | 158″ | 585,000 | 750,000 | 690,000 | 1 |
Specifications subject to change without notice. Check with manufacturer for critical specification requirements.
* Actual fuel consumption will vary with operating conditions. † Based on Category I Afterburner, Category II will be higher.